--------------- INITIAL DESIGN ---------------
  EFFICIENCY =  0.40208535492298758     
  STALL TORQUE =   52.444064003338482     
  RUNNING TORQUE =   21.689973529872642     
  FLUX DENSITY =   6.4106695269611782     
  IRON LOSSES =   8.0616186651882202     
  D.C. RESISTANCE =   35.536609531541529     
  A.C. RESISTANCE =   1640.4894040831223     
  ROTOR RESISTANCE =   26.483703287927796     
  LEAKAGE REACTANCE =   81.854424161442168     
  MAGNETIZING REACTANCE =   126.23722902182682     
  STATOR COPPER LOSSES =   15.328768131509099     
  ROTOR COPPER LOSSES =   6.8673928349394133     
  NO LOAD CURRENT =  0.91098324076898207     
  FULL LOAD CURRENT =  0.12473324160149871     
  STALL CURRENT =   1.1197994372633948     
 ---------------- OPTIMIZED DESIGN -----------------
  EFFICIENCY =  0.73125230674649877     
  STALL TORQUE =   60.000641547978056     
  RUNNING TORQUE =   53.286722451450117     
  FLUX DENSITY =   4.6280995822050164     
  IRON LOSSES =   2.4234768440929364     
  D.C. RESISTANCE =   39.388063734878571     
  A.C. RESISTANCE =   5457.0358418051565     
  ROTOR RESISTANCE =   15.022232981436693     
  LEAKAGE REACTANCE =   47.628065275749300     
  MAGNETIZING REACTANCE =   201.08710308898480     
  STATOR COPPER LOSSES =   8.8295496919697971     
  ROTOR COPPER LOSSES =   25.676343646138822     
  NO LOAD CURRENT =  0.57189147505452076     
  FULL LOAD CURRENT =  0.33512643928430041     
  STALL CURRENT =   1.5903478743821653